Carrier 48fc 15 ton.

IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Exclusive IGC solid-state control for on-board diagnostics ...We would like to show you a description here but the site won’t allow us. 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ... 48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = 460/3/600 = Electromechanical Controls ca

1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).

6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.25SCA5. Up to 15.2 SEER2 for moderate energy savings with standard comfort features. 4.5 out of 5 stars. 32 Reviews. 5 Star. 69%. 4 Star. 22%. 3 Star.

SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drainView and Download Carrier 48HC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R-410A) Refrigerant Sizes: 04, 05, 06. 48HC air conditioner pdf manual download. Also for: 48hc series, 48hc-a04, 48hc-a05, 48hc-a06.This manual is also suitable for: View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A Refrigerant. WeatherMaker Puron 48FC 04 Series air conditioner pdf manual download.Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;

How much is 200 us dollars in jamaican dollars

With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ...

CE - Carrier EnterpriseCarrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 and Energy Star compliant. Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Gas efficiencies up to 82% Standard cooling operating … 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000; Orissa Bengal Carrier News: This is the News-site for the company Orissa Bengal Carrier on Markets Insider Indices Commodities Currencies Stocks6 to 23 Nominal Tons. 50LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have the some of the industry’s highest IEERs available. The multi stage cooling compressor allows for added comfort, energy savings and humidity control.

Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ...48VG. Gas heating and electric cooling with up to 16 SEER2 for enhanced energy savings with enhanced comfort features. Ultra-low NOx models available for California. 4.7 out of 5 stars. 45 Reviews. 5 Star. 80%. 4 Star. 13%.Description. 48FCFM16A3A6-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 …Carrier delivers efficient, dependable performance, inside and out. With Carrier split systems, a wide range of outdoor air conditioners and heat pumps works seamlessly with innovative indoor air handlers to create reliable solutions that are easy-to-install and service for a wide range of commercial HVAC needs. 10 Product (s)7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.

American Airlines is ending the AirPass program, which offered fixed rates for travel and a ton of lucrative perks. While most travelers purchase airline tickets directly from the ...Carrier West Training – HVAC Training

View and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ...Carrier air conditioners, for example, offer a variety of energy efficiency or SEER2* ratings, various types of comfort-enhancing technologies and even sound ratings. Installed costs might range from anywhere between $3,000 to $15,000 or more.3 to 12.5 Nominal Tons. Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The …Carrier West Training – HVAC Training Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup- 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA04A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON;SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain See moreOrissa Bengal Carrier News: This is the News-site for the company Orissa Bengal Carrier on Markets Insider Indices Commodities Currencies Stocks50FCQ 04 -28, 50GCQ 04-06 Single Package Rooftop Heat Pump Units with SystemVuTM Controls Version 3.X and Puron R-410A Refrigerant Controls, Start-Up, Operation and Troubleshooting Instructions IMPORTANT: This literature covers 50FCQ 04 -28 and 50GCQ 04-06 models with SystemVu controls version 3.X...

James avery donation request

GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …

48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... Carrier provides a full line of packaged rooftop equipment to meet demanding HVAC systems requirements, from small electric cooling units to large gas heat/electric cooling units like the WeatherExpert® series, which has the industry’s highest part-load performance IEER ratings in the 3-5 ton range. Carrier DOAS (Dedicated Outdoor Air Systems) are …48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES.Nominal Capacity (Ton): 15 Ton. Efficiency: Standard. Voltage (Phase): 208/230 V 3-Phase. California Prop 65: False. Capacity Modulation: 2-Stage. Category: Packaged …Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input 250000; Compressor Stage 1; Equipment Type Commercial Packaged …30 to 100 Nominal Tons. 48P2 – Vertical CV/SAV. 48P3 – Vertical VAV. 48P4 – Horizontal CV/SAV. 48P5 – Horizontal VAV. Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels.Description. 48FCFM16A3A6-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 …Time to clean out your attic or garage? Forget about settling for garage sale prices. These days, online auction sites and marketplaces make it easier than ever before to sell your...

Supply Width 15.52 Return Length 37.921 Return Width 15.799 RW RL SW SL CW CL Table 5. Curb matrix Type Trane Lennox Carrier Bryant JCI/York ICP Heil Day and Nigh Goodman Daikin Older Voyager Gas/Electric GCC036-060 ZGB 036-060 48DJ 004-00, 48GJ 006 48HC 004-006, 48HE 004-006 48HJ 004-006, 48KC 004-006 48LJ 004-006, …CE - carrierenterprise.comCarrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News. Home; 2024-03-04; 2024-03-03; 2024-03-02; ... Carrier 48FC Single Package Rooftop Gas Heat-Electric Cooling Units Instruction Manual.Sizes 04-06 models use single-stage cool-ing capacity control. FEATURES. Standard Base Unit Cabinet. Puron (R-410A) HFC refrigerant • Access panels with easy grip handles. SEER of 14.0 • Innovative, easy starting, no-strip screw feature on unit. Meets or exceeds ASHRAE 90.1 energy efficiency levels access panels.Instagram:https://instagram. eye center chipley fl 48KC Sizes 04 to 06 Single Packaged Rooftop Units with Gas Heat. Product Data WeatherMaker®. Gas Heat/Electric Cooling Packaged Rooftop Units. 3 to 5 Nominal Tons. 2. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install ... don shipley height Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for Delivery; … ubs arena capacity concerts 6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...Carrier Manuals. Air Conditioner. 48TC series. Product data. Carrier WeatherMaker 48TC Series Product Data. Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons. Also See for WeatherMaker 48TC Series: Service and maintenance instructions (112 pages) , Installation instructions manual (64 pages) , crip mac released Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE, 10 TON STAGE HEAT ROOFTOP GAS/ELECTRIC PACKAGE UNIT, VOLTAGE:460, HERTZ:60, PHASE:3, REFRIGERANT:R-22, CFM:4000, AFUE:80%, EER:9, ... WeatherMaker® 48FC Single … honeywell pro 5000 setup manual 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are panera bread warrenton menu 30 to 100 Nominal Tons. 48P2 – Vertical CV/SAV. 48P3 – Vertical VAV. 48P4 – Horizontal CV/SAV. 48P5 – Horizontal VAV. Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels. rally house allen park This product has been superseded by. 48FCEA04A3A5-0A0A0 - 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. kawasaki 23 hp oil filter cross reference Carrier48ES, 48VL, 48XL Small Packaged Products Air Conditioner / Gas Furnace Family REVIT Files. 48XZ, 48VT, 48XT Small Packaged Products Air Conditioner / Hybrid Heat Family REVIT Files. 50ES, 50VL, 50XL Small Packaged Products Air Conditioner Family REVIT Files. 50EZ, 50VT, 50XT Small Packaged Products Heat Pump Family REVIT Files. kent state football message board With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ... Carrier’s new Gas Heat/ Electric Cooling WeatherExpert® 6 to 10 ton commercial packaged rooftop models are designed to provide total low cost of ownership by providing some of the highest cooling efficiencies in the industry, with low installed costs, low maintenance costs, and high reliability. These models focus on providing high buffalo grove animal hospital reviews IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit dr nicholai stephens Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;Description. 48FCFM24A3A5-6F0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Models. 24 = 20 Tons. A = No Smoke Detector or CO 2 Sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu.